EVP-200℃ New Energy Vehicle Power Shielded Cable

Flexible electromagnetic shielding cable for high-voltage battery systems inside electric vehicles.

Product Inquiry:

Product Features:

◆ Operating Temperature: -60℃~+200℃
◆ Silicone material has excellent flexibility, easy to install and use
◆ High temperature resistance, fire resistance, wear resistance, oil resistance, tensile resistance
◆ Good EMI\EMC electromagnetic interference resistance
◆ Rated Voltage: 1500V
◆ Halogen-free, compliant with ROHS standards
◆ Easy to bend, bending radius ≥ 5D


Technical Parameters:

◆ Conductor: Electrolytic oxygen-free copper wire

◆ Insulation: High-temperature silicone

◆ Shielding: Tinned copper wire braid + Mylar wrapping

◆ Sheath: High-temperature silicone

 

Current carrying capacity curve of unshielded cable, suitable for automotive wiring

Cable Specifications

Conductor

Insulation Outer Diameter

Shielding (≥80%)

Conductor Structure n/mm

Stranded Outer Diameter mm

Resistance   AT   20℃   (Ω/KM)

Braiding Structure

Wrapping

Sheath Outer Diameter

EV1×0.5 Unshielded

28/0.15AS

0.92

37.10

2.3±0.10

16/5/0.10TD

Al-mylar

4.03±0.15

EV1×0.75 Unshielded

24/0.20AS

1.13

24.70

240±0.10

16/5/0.10TD

Al-mylar

4.50±0.15

EV1x1.0 Unshielded

32/0.20AS

1.40

18.50

2.70±0.10

16/6/0.10TD

Al-mylar

4.70±0.15

EV1x1.5 Unshielded

49/0.20AS

1.62

12.70

3.00±0.10

16/7/0.10TD

Al-mylar

5.10±0.15

EV1×2.0 Unshielded

64/0.20AS

1.85

9.42

3.20±0.10

16/7/0.10TD

Al-mylar

5.30±0.15

EV1×2.5 Unshielded

49/0.25AS

2.06

7.60

3.50±0.15

16/8/0.10TD

Al-mylar

5.60±0.15

EV1×3.0 Unshielded

98/0.20AS

2.45

6.15

4.00±0.15

16/7/0.127TD

Al-mylar

5.30±0.20

EV1×4.0 Unshielded

133/0.20AS

2.85

4.71

4.60±0.15

16/7/0.27TD

Al-mylar

7.30±0.20

EV1×5.0 Unshielded

161/0.20AS

3.16

3.94

480±0.15

16/8/0.127TD

Al-mylar

7.40±0.20

EV1×6.0 Unshielded

190/0.20AS

3.47

3.14

5.10±0.15

16/9/0.127TD

Al-mylar

7.70±0.20

EV1×10 Unshielded

323/0.20AS

4.51

1.82

6.70±0.20

16/8/0.15TD

Al-mylar

9.60±0.20

EV1×16 Unshielded

513/0.20AS

5.70

1.16

8.00±10.20

16/8/0.20TD

Al-mylar

10.09±0.25

EV1×25 Unshielded

798/0.20AS

7.20

0.74

9.80±0.25

16/10/0.20TD

Al-mylar

12.09±0.30

EV1×35 Unshielded

1121/0.20AS

8.41

0.53

1140±0.25

36/5/0.20TD

Al-mylar

14.50±0.30

EV1×5 Unshielded

1586/0.20AS

10.03

0.37

13.50±0.25

36/6/0.20TD

Al-mylar

17.00±0.35

EV1×70 Unshielded

1387/0.254AS

11.90

0.26

17.00±0.30

36/6/0.2TD

Al-mylar

21.00±0.35

EV1×95 Unshielded

1887/0.254AS

13.90

0.20

19.30±0.30

36/9/0.20TD

Al-mylar

24.00±0.50

EV1×120 Unshielded

2368/0254AS

15.10

0.15

22.00±0.30

36/10/0.20TD

Al-mylar

27.00±0.50


Tag:

Product Inquiry

If you are interested in our products, please leave your email to get a free product quote, thank you!

Submit Message

Related Products

Used for wiring between work area communication outlets and patch panels in building structured cabling systems, as well as wiring between user communication outlets and patch panels in residential structured cabling systems. Supports 100MHz data communication, including ISDN, 10Mbps Ethernet, 100Mbps Fast Ethernet, Gigabit Ethernet, 4/16Mbit/s Token Ring, TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s. The standard wiring length is 90 meters. Color coding is done according to ANSI/TIA/EIA-568-B.

View Details +

Category 6 cable, used for network cabling projects, wiring between work area communication outlets and patch panels in building structured cabling systems, as well as wiring between user communication outlets and patch panels in residential structured cabling systems. Supports 100MHz data communication including ISDN, 10Mbps Ethernet, 100Mbps Fast Ethernet, and Gigabit Ethernet. Color-coded according to ANSI/TIA/EIA-568-B standards. Suitable for all Class D and Class E channel applications. Complies with Category 6 standards specified in EN50173, ISO 11801 second edition, or EIA/TIA568B.2-1.

View Details +

Category 6 cable, used for network cabling projects, wiring between work area communication outlets and patch panels in building structured cabling systems, as well as wiring between user communication outlets and patch panels in residential structured cabling systems. Supports 100MHz data communication including ISDN, 10Mbps Ethernet, 100Mbps Fast Ethernet, and Gigabit Ethernet. Color-coded according to ANSI/TIA/EIA-568-B. Suitable for all Class D and Class E channel applications. Complies with Category 6 standards specified in EN50173, ISO 11801 second edition, or EIA/TIA568B.2-1.

View Details +

Category 6 cables, used for network cabling projects, wiring between work area communication outlets and patch panels in building structured cabling systems, as well as wiring between user communication outlets and patch panels in residential structured cabling systems. They support 100MHz data communication including ISDN, 10Mbps Ethernet, 100Mbps Fast Ethernet, and Gigabit Ethernet, and are color-coded according to the ANSI/TIA/EIA-568-B standard. Suitable for all Class D and Class E channel applications. Compliant with Category 6 standards specified in EN50173, ISO 11801 second edition, or EIA/TIA568B.2-1.

View Details +

< 1...111213...43 >