undefined
+
  • undefined

EVP-200℃ New Energy Vehicle Power Shielded Cable

Flexible electromagnetic shielding cable for high-voltage battery systems inside electric vehicles.

Product Inquiry:

Product Features:

◆ Operating Temperature: -60℃~+200℃
◆ Silicone material has excellent flexibility, easy to install and use
◆ High temperature resistance, fire resistance, wear resistance, oil resistance, tensile resistance
◆ Good EMI\EMC electromagnetic interference resistance
◆ Rated Voltage: 1500V
◆ Halogen-free, compliant with ROHS standards
◆ Easy to bend, bending radius ≥ 5D


Technical Parameters:

◆ Conductor: Electrolytic oxygen-free copper wire

◆ Insulation: High-temperature silicone

◆ Shielding: Tinned copper wire braid + Mylar wrapping

◆ Sheath: High-temperature silicone

 

Current carrying capacity curve of unshielded cable, suitable for automotive wiring

Cable Specifications

Conductor

Insulation Outer Diameter

Shielding (≥80%)

Conductor Structure n/mm

Stranded Outer Diameter mm

Resistance   AT   20℃   (Ω/KM)

Braiding Structure

Wrapping

Sheath Outer Diameter

EV1×0.5 Unshielded

28/0.15AS

0.92

37.10

2.3±0.10

16/5/0.10TD

Al-mylar

4.03±0.15

EV1×0.75 Unshielded

24/0.20AS

1.13

24.70

240±0.10

16/5/0.10TD

Al-mylar

4.50±0.15

EV1x1.0 Unshielded

32/0.20AS

1.40

18.50

2.70±0.10

16/6/0.10TD

Al-mylar

4.70±0.15

EV1x1.5 Unshielded

49/0.20AS

1.62

12.70

3.00±0.10

16/7/0.10TD

Al-mylar

5.10±0.15

EV1×2.0 Unshielded

64/0.20AS

1.85

9.42

3.20±0.10

16/7/0.10TD

Al-mylar

5.30±0.15

EV1×2.5 Unshielded

49/0.25AS

2.06

7.60

3.50±0.15

16/8/0.10TD

Al-mylar

5.60±0.15

EV1×3.0 Unshielded

98/0.20AS

2.45

6.15

4.00±0.15

16/7/0.127TD

Al-mylar

5.30±0.20

EV1×4.0 Unshielded

133/0.20AS

2.85

4.71

4.60±0.15

16/7/0.27TD

Al-mylar

7.30±0.20

EV1×5.0 Unshielded

161/0.20AS

3.16

3.94

480±0.15

16/8/0.127TD

Al-mylar

7.40±0.20

EV1×6.0 Unshielded

190/0.20AS

3.47

3.14

5.10±0.15

16/9/0.127TD

Al-mylar

7.70±0.20

EV1×10 Unshielded

323/0.20AS

4.51

1.82

6.70±0.20

16/8/0.15TD

Al-mylar

9.60±0.20

EV1×16 Unshielded

513/0.20AS

5.70

1.16

8.00±10.20

16/8/0.20TD

Al-mylar

10.09±0.25

EV1×25 Unshielded

798/0.20AS

7.20

0.74

9.80±0.25

16/10/0.20TD

Al-mylar

12.09±0.30

EV1×35 Unshielded

1121/0.20AS

8.41

0.53

1140±0.25

36/5/0.20TD

Al-mylar

14.50±0.30

EV1×5 Unshielded

1586/0.20AS

10.03

0.37

13.50±0.25

36/6/0.20TD

Al-mylar

17.00±0.35

EV1×70 Unshielded

1387/0.254AS

11.90

0.26

17.00±0.30

36/6/0.2TD

Al-mylar

21.00±0.35

EV1×95 Unshielded

1887/0.254AS

13.90

0.20

19.30±0.30

36/9/0.20TD

Al-mylar

24.00±0.50

EV1×120 Unshielded

2368/0254AS

15.10

0.15

22.00±0.30

36/10/0.20TD

Al-mylar

27.00±0.50


Tag:

Product Inquiry

If you are interested in our products, please leave your email to get a free product quote, thank you!

Submit Message

Related Products

Halogen-free design protects personnel and fixed assets during fires by reducing smoke density and corrosive gases. It is suitable for densely populated and high-value property areas where protecting people and property in fire situations is crucial. Used in public buildings, transportation systems, and factories for data processing, measurement and control engineering, security systems, and cables. Suitable for computer system data wiring with transmission rates below 10MB per second, compatible with RS422 and RS485 series interfaces. Applicable for fixed installations or occasional movement, transmitting low-sensitivity signals and high bit-rate signals in control and measurement cables. Suitable for machine tool manufacturing, complete equipment installation projects, power plants, heating and air conditioning systems, office automation equipment, and data processing systems. Used in mechanical instruments and electronic devices requiring shielded anti-interference wiring. The overall braided layer minimizes electrical interference; the twisted pair (TP) structure allows circuit decoupling (crosstalk effect). Polyethylene has good mechanical properties, excellent electrical insulation, and chemical stability. Uses a new double-layer shielding with aluminum foil Mylar and copper mesh braiding, effectively resisting electromagnetic interference.

View Details +

Suitable for multi-bus systems based on RS485/RS422, offering 2-core, 4-core, and 6-core options, with a PUR outer sheath that provides tear and impact resistance. When used in power drag chain systems, it features resistance to mineral oil and abrasion, and is also suitable for outdoor use within a temperature range, as well as for high-flexibility applications (power drag chains, moving mechanical parts) bus system cables.

View Details +

CC-Link control and communication link fieldbus network cables provide efficient and integrated manufacturing and process automation for control and information data. Suitable for high-flexibility applications in power drag chains and moving mechanical parts, with a PUR outer sheath that is tear-resistant and impact-resistant. When used in power drag chain systems, it is resistant to mineral oil and wear, and is also suitable for outdoor use within a temperature range, making it a highly flexible bus cable.

View Details +

< 1...8910...43 >