QVR Automotive Wire
Suitable for dry or humid environments, especially for the installation and safe laying of vehicle electrical and instrument wiring. The insulation materials used have excellent resistance to solvents and greases, as well as heat resistance that meets the specified temperature rating.
Category:
Product Structure
◆Conductor: Multi-strand fine twisted oxygen-free copper wire or tinned copper wire
◆Insulation: 105℃ flame-retardant PVC
◆Color: Any color
Technical Parameters:
◆Standard: GB9238-88
◆Withstand Voltage Test: 2.5KV
◆Rated Temperature: 105℃
◆Insulation resistance at 70℃ ≥ 10⁹ Ω·m volume resistivity
Model Specifications:
| Model | Specification | Conductor Structure (mm) | Insulation Diameter (mm) | Conductor Resistance (Ω/KM) |
| QVR | 0.2mm2 | 12/0.15 | 1.24 | 92.3 |
| QVR | 0.3mm2 | 16/0.15 | 1.35 | 69.2 |
| QVR | 0.5mm2 | 16/0.2 | 2.2 | 39 |
| QVR | 0.75mm2 | 24/0.2 | 2.5 | 26 |
| QVR | 1.0mm2 | 32/0.2 | 2.6 | 16.8 |
| QVR | 1.5mm2 | 30/0.25 | 3.0 | 13.3 |
| QVR | 2.5mm2 | 49/0.25 | 3.8 | 7.98 |
| QVR | 4mm2 | 56/0.3 | 4.6 | 4.95 |
| QVR | 6mm2 | 84/0.3 | 5.2 | 3.3 |
Note: Tinned copper conductor cables need to be customized; packaging length and insulation color can be customized according to customer requirements.
Specific parameters are subject to the product specification sheet.
Tag:
Related Products
Suitable for control circuits with a rated voltage of 450/750V and below, laid in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, and protection lines, as well as signal transmission, control, and measurement of electrical instruments and distribution devices. This type of product has strong electromagnetic interference resistance and is suitable for fixed locations requiring shielding.
Suitable for control with a rated voltage of 450/750V and below, laid in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, and protection lines, as well as signal transmission, control, and measurement of electrical instruments and distribution devices.
Suitable for control with a rated voltage of 450/750V and below, installed in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, protection circuits, signal transmission, control, and measurement in electrical instruments and distribution devices.
Copper core PVC insulated flat wire, used for internal wiring installation in electrical appliances, instruments, electronic devices, and automation equipment, with a rated communication voltage of 300/300V and below.