undefined
undefined
+
  • undefined
  • undefined

Indoor wiring optical cable GJFJV

Product Inquiry:

Product Applications

● Indoor structured cabling
● Backbone cabling cable for buildings
● Multi-core fiber flexible jumper


Product Features

● Uses tight-buffered fiber, easy to strip and use
● Flame retardant (or non-flammable) performance meets standard requirements;
● Outer sheath material has corrosion resistance, waterproof, UV resistance, and environmental protection characteristics;
● Soft, flexible, easy to splice, supports high-capacity data transmission;
● Aramid reinforcement elements provide excellent tensile performance for the cable


Indoor Cabling Cable Structure Parameters

Cable Structure
Cross-section Diagram

Number of Fibers
Fiber
Quantity

Cable Diameter
Cable Diameter
Millimeters

Cable Reference Weight
(kg/km)
Cable Weight
(Reference)

Allowable Tensile Force
Tensile Strength
Long-term/Short-term
Long/Short Term
Newtons

Allowable Crushing Force
Crush Resistance Performance
Long-term/Short-term
Long/Short Term
Newtons

Minimum Bending Radius
Bending Radius
Dynamic/Static
Dynamic/Static
Millimeters

Transport/Storage Operating Temperature
Transport/Storage/
Operating Temperature

Without Reinforcement Core

4

5.0

17

70/220

300/1000

20D/10D

-20℃—+60℃

6

5.2

21

100/300

300/1000

8

5.5

28

130/440

300/1000

12

6.5

36

300/600

300/1000

16

7.5

44

350/700

300/1000

24

8.0

59

400/800

300/1000

Sub-unit Structure

36

18.5

241

400/1320

300/1000

48

19.5

316

400/1320

300/1000

72

27.8

686

400/1320

300/1000

96

30.3

818

600/1500

300/1000

144

34.7

1109

1000/1600

300/1000

Note: All values in the table are for reference only; dimensions and weight are calculated based on φ0.9 tight-buffered fiber; when using G.657 fiber, the static minimum bending radius is 5D


Tag:

Product Inquiry

If you are interested in our products, please leave your email to get a free product quote, thank you!

Submit Message

Related Products

Suitable for control circuits with a rated voltage of 450/750V and below, laid in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, and protection lines, as well as signal transmission, control, and measurement of electrical instruments and distribution devices. This type of product has strong electromagnetic interference resistance and is suitable for fixed locations requiring shielding.

View Details +

Suitable for control with a rated voltage of 450/750V and below, laid in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, and protection lines, as well as signal transmission, control, and measurement of electrical instruments and distribution devices.

View Details +

Suitable for control with a rated voltage of 450/750V and below, installed in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, protection circuits, signal transmission, control, and measurement in electrical instruments and distribution devices.

View Details +

Copper core PVC insulated flat wire, used for internal wiring installation in electrical appliances, instruments, electronic devices, and automation equipment, with a rated communication voltage of 300/300V and below.

View Details +