Applications of large logarithmic communication cables: Mainly used for transmitting audio and analog signals at 150kHz and below, as well as digital signals at 2048kbit/s and below. Under certain conditions, they can also be used to transmit digital signals above 2048kbit/s. Introduction to HYV and HSYV indoor large logarithmic communication cables: Used for audio connections between program-controlled switch main distribution frames and exchange users, and can also be used for audio connections between other communication devices. They support low-rate data transmission, voice applications, digital telephony, fax, program-controlled switches, digital device connections, branches and trunks of integrated telecommunications systems, etc. Conductor diameters (mm): 0.40, 0.50, 0.60, 0.70, 0.80, 0.90.

Product Inquiry:

Product Description:

◆ 24AWG wire gauge
◆ HYA 10-pair, 20-pair, 30-pair, 50-pair, 100-pair twisted pair structure
◆ Reference standards: UL 444, TIA/EIA-568C
◆ Complies with YD/T 322-1996 regulations,
◆ Performance exceeds TIA/EIA 568B standard requirements, suitable for high-speed voice backbone transmission
◆ Test bandwidth far exceeds the 16MHz Cat.3 physical bandwidth standard
◆ Flame retardant meets IEC 60332-1 standard
◆ Selected high-quality materials provide excellent mechanical properties to the cable


Product Performance:

◆ Single conductor DC resistance: 148 ohms/km
◆ Electrical strength duration: 1 minute
◆ Propagation speed: 65%
◆ Propagation delay difference: 45 nanoseconds/100 meters
◆ Maximum operating capacitance: 800Hz/km 10 pairs ≤58
◆ Maximum conductor balance: ≤5% (@20℃)
◆ Minimum insulation resistance: 5000 megaohm·km
◆ Ground capacitance balance: ≤250 pF/km
◆ Electrical strength between conductors: 1 kilovolt


Mechanical Properties:

◆ Operating temperature: -20~50℃
◆ Cable net weight: 0.84 kg/m
◆ Conductor material purity: 99.99%
◆ Insulation material: density 1.5 g/cm³
◆ Minimum sheath thickness: 1.6 millimeters
◆ Insulation outer diameter: 0.88±0.02 millimeters
◆ Conductor elongation at break: ≥15%
◆ Nominal conductor diameter: 0.5±0.005 millimeters
◆ Insulation integrity: DC spark test 1.5-6 kilovolts


Tag:

Product Inquiry

If you are interested in our products, please leave your email to get a free product quote, thank you!

Submit Message

Related Products

Suitable for control circuits with a rated voltage of 450/750V and below, laid in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, and protection lines, as well as signal transmission, control, and measurement of electrical instruments and distribution devices. This type of product has strong electromagnetic interference resistance and is suitable for fixed locations requiring shielding.

View Details +

Suitable for control with a rated voltage of 450/750V and below, laid in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, and protection lines, as well as signal transmission, control, and measurement of electrical instruments and distribution devices.

View Details +

Suitable for control with a rated voltage of 450/750V and below, installed in fixed locations such as indoors, cable trenches, conduits, and direct burial. Used for control, monitoring circuits, protection circuits, signal transmission, control, and measurement in electrical instruments and distribution devices.

View Details +

Copper core PVC insulated flat wire, used for internal wiring installation in electrical appliances, instruments, electronic devices, and automation equipment, with a rated communication voltage of 300/300V and below.

View Details +